With in-depth filter elements, the slower the flow, the more efficient the filter element is and the longer the user can go between change-outs. We typically size housings to start out with a clean differential pressure of two pounds or less.


Instruction

1. The differential pressure across both the filter element and housing must be considered cumulatively. The pressure drop across the housing differs from housing to housing, but in most cases, it can be obtained from the housing manufacturer.


2. Assuming a cartridge vessel is designed for cartridges with a one-inch inside diameter, keep in mind that the flow through the bottom of each filter should not exceed 15-25 gallons per minute (for membrane pre-filters, try not to exceed 15 gpm). 


3. These flow rates should not be exceeded because turbulent flow is created on the interior core of the filter element, which frequently cause unloading of contaminant from the filter media.


4. Always consider the viscosity of the material to be filtered when sizing filters or vessels. Also keep in mind that the viscosity of most materials varies depending on temperature. There are many filter elements in WUZHOU KINGDA, if you are interested in our products, please feel free to contact us!


5. If you have an application where the customer does not want to go over a certain differential pressure and the temperature of the product can go through a wide swing, be careful to find out what the viscosity of the liquid is at both extremes of temperature.


RECOMMENDED PRODUCTS
Pleated filter cartridge for liquids

Pleated-filter-...

Industrial sintered stainless steel mesh filter element

Industrial-sint...

Sintered stainless steel filter element

Sintered-stainl...

Stainless steel pleated filter cartridge

Stainless-steel...

Hydraulic oil filter cartridge

Hydraulic-oil-f...

Cylindrical oil filter element

Cylindrical-oil...